RNS and RWS Series flowmeters

| By Chemical Engineering

The RNS and RWS Series flowmeters are designed to measure non-condensing steam and saturated process steam at pressures of up to 150 psi in energy-related applications. Both series types have no moving parts and require negligible maintenance. All meters in the series are loop-powered devices with standard HART communication for field programming. Operating temperatures for the meters are –20 to 366°F. An internal resistance temperature detector (RTD) and an external pressure sensor provide data to the flowmeter software, which compensates for changes in temperature and pressure to achieve accuracies of ±1%. — Racine Federated, Racine, Wisc.

http://www.racinefed.com